Golf Course Under-grass Heating - Heating Pads

Coloured blocks

Inditherm heater pads are mounted on insulation and encapsulated in rugged outer covers with hot weld seams to ensure that each unit is sealed and waterproof. Pads typically measure 10m x 0.5m (33' x 20") but may vary in length to fit around the edges of greens, ensuring heating over the entire area.

The pads are typically laid at a depth of 250mm to 300mm (10" to 12") under greens and around 200mm (8") under tees. This means that it is necessary to rebuild the green or tee, or install the system when the golf course is under construction. The pads are wired in groups of 4 to waterproof junction located on the base drainage layer. Cables run power at low voltage (50V) from power control panels discretely located adjacent to each playing area.

The pads are spaced to allow for efficient drainage and optimum heating of the playing surfaces. The spacing depends upon the expected ambient conditions and therefore varies from a minimum of 500mm (20") up to 800mm (32"). On a typical green with pads spaced at 600mm (24"), there would be an average of around 50 pads. Detailed tests have proven that this arrangement has no adverse effects on drainage under a well-designed playing surface.

Pad orientation will depend upon a number of factors, such as the configuration of the drainage and sprinkler systems, and the location of the control panel.

Each heating pad is designed to work up to approximately 30°C (86°F). The sand layer has good heat dissipation properties and storage capabilities that help to keep the surface frost free without damaging the grass roots.